OPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEAROPENCLOSESTOPCALRUN SCROLLSCROLLSETCLEARSection 8: TroubleshootingThese operators display their status on the integrated display. Each time the operatorruns, stops, reverses or refuses to run, the display will indicate why the action did, or didnot, take place.Once an error code has been generated, the operator will continue to display theerror code while the operator is not running. This error code can be cleared by pressingthe STOP button or STOP key on the keypad. The error code will automatically clearwhen the operator stops at the down limit. Error codes will continue to be stored in theoperator’s Error Code Memory after they have been cleared from the display in theRun Mode.Display Operation in Run ModeTo aid in troubleshooting problems, these operators include an error code memory thatstores the last 10 error events. These codes are stored with or without power. The lasterror code detected is also displayed on the LCD until the stop button or key is pressedor the operator stops at the down limit.The error code memory stores the last 10 error codes in sequence. Once 10 codes arestored, the oldest code is erased to make room for the newest code. These codes aredisplayed in calibration mode. The display will flash the number of the error code andthe 2-digit error code followed by a description of the error code. Fig. 1 & 2.Error CodesERROR CODE 1 41Figure 1REV ONE BUTTONFigure 23.18.1www.geniecompany.com 08-12Counter Door OperatorGCL-GCX