GCL-GCXSection 10: Appendix CRun Code DisplaysConditionCode DISPLAY Condition Code Description0C IDLE > DOWN LIMIT STANDING BY AT DOWN LIMIT (NOTE: THIS MESSAGE IS DISPLAYED IF BOTH LIMITS ARE ACTIVE)0D IDLE > UP LIMIT STANDING BY AT UP LIMIT0E IDLE > MID STOP STANDING BY AT MID-STOP LIMIT0F IDLE > NO LIMIT STANDING BY BETWEEN LIMITS10 OPENING > OPEN BTN OPENING FROM OPEN BUTTON11 OPENING > ONE BTN OPENING FROM 1 BUTTON12 OPENING > RADIO OPENING FROM RADIO13 OPENING > AUX OPEN OPENING FROM AUXILIARY OPEN INPUT14 OPENING > OPEN KEY OPENING FROM KEYPAD OPEN KEY20 CLOSING > CLOSE PB CLOSING FROM CLOSE BUTTON21 CLOSING > ONE BTN CLOSING FROM 1 BUTTON22 CLOSING > RADIO CLOSING FROM RADIO24 CLOSING > CLOSE KP CLOSING FROM KEYPAD CLOSE KEY2A CLOSING > TCM CLS CLOSING FROM TIMER CLOSE MODULE2B CLOSING > FDM CLS CLOSING FROM FORE DOOR MODULE30 HALT > WALL BUTTON GDO STOPPED BECAUSE STOP OR OPEN BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL31 HALT > ONE BUTTON GDO STOPPED BECAUSE 1 BUTTON WAS ACTIVATED, POSSIBLY STARTING A REVERSAL32 HALT > RADIO GDO STOPPED BECAUSE RADIO INPUT WAS ACTIVATED, STARTING A REVERSAL33 HALT > AUX. OPEN GDO STOPPED BECAUSE AUXILIARY OPEN INPUT WAS ACTIVATED, STARTING A REVERSAL34 HALT > KEYPAD KEY GDO STOPPED BECAUSE KEYPAD STOP OR OPEN KEY WAS ACTIVATED, POSSIBLY STARTING A REVERSAL35 HALT > N-O SAFETY GDO STOPPED BECAUSE N-O REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL36 HALT > ODC STB GDO STOPPED BECAUSE ODC STB WAS BLOCKED, STARTING A REVERSAL37 HALT > N-C SAFETY GDO STOPPED BECAUSE N-C REVERSING INPUT WAS ACTIVATED, STARTING A REVERSAL38 HALT > MON. EDGE GDO STOPPED BECAUSE MONITORED EDGE SENSOR INPUT WAS ACTIVATED, STARTING A REVERSAL39 HALT > DOOR FORCE GDO STOPPED BECAUSE THE FORCE REQUIRED TO OPERATE THE DOOR WAS TOO HIGH, POSSIBLY STARTING A REVERSAL3A HALT > LOSS OF C/C GDO STOPPED BECAUSE CONSTANT CONTACT ON CONTROL REMOVED BEFORE REACHING A LIMIT, POSSIBLY STARTING A REVERSAL3B HALT > SHUTDOWN GDO STOPPED BECAUSE THE GDO DETECTED A FAULT SUCH AS AN OPEN INTERLOCK, OVERHEATED MOTOR, ETC.3C HALT > DOWN LIMIT GDO STOPPED BECAUSE IT REACHED THE DOWN LIMIT3D HALT > UP LIMIT GDO STOPPED BECAUSE IT REACHED THE UP LIMIT3E HALT > MID STOP GDO STOPPED BECAUSE IT REACHED THE MID-STOP LIMIT3F HALT > MODULE FAIL GDO STOPPED BECAUSE AN EXPANSION MODULE WAS NOT WORKING PROPERLY40 REV > OPEN BUTTON GDO REVERSED BECAUSE THE OPEN BUTTON WAS ACTIVATED41 REV > ONE BUTTON GDO REVERSED BECAUSE THE 1 BUTTON WAS ACTIVATED42 REV > RADIO GDO REVERSED BECAUSE THE RADIO INPUT WAS ACTIVATED43 REV > AUX OPEN GDO REVERSED BECAUSE THE AUXILIARY OPEN INPUT WAS ACTIVATED44 REV > OPEN KEY GDO REVERSED BECAUSE THE KEYPAD OPEN KEY WAS ACTIVATED45 REV > N-O SAFETY GDO REVERSED BECAUSE THE N-O REVERSING INPUT WAS ACTIVATED10.5www.geniecompany.com 08-12Counter Door Operator