5 - 38 Genie S-60 & Genie S-65 Part No. 65196Third Edition • First PrintingSection 5 • Troubleshooting Flow ChartsChart 18TurntableRotate LeftFunctionInoperativeBe sure all otherfunctions operatenormally.With key switch turnedto ground controls andboth Emergency Stopbuttons pulled out to theON position, hold thefunction enable switch toeither side and move theturntable rotate toggleswitch TS17 in the LEFTdirection. Check voltageon wht/red-4 wire onturntable rotateproportional valve coil(item S).0V12V or moreHold the function enableswitch to either side andmove the turntablerotate toggle switch inthe LEFT direction andcheck voltage at TB6.4 to 6VRepair open in wht/red-4wire circuit from TB6 toturntable rotateproportional valve coilOR repair open in brnground wire circuit tovalve coil.0VWith key switch turnedto platform controls andboth Emergency Stopbuttons pulled out to theON position, press downthe foot switch andmove turntable rotatecontroller in the LEFTdirection and checkvoltage at TP6.Continued on the nextpage.Repair open in wht/redwire from TP6 to TB6.0VPress down the footswitch and checkvoltage at terminal "+"on controller.12V or more0V Repair open in powersupply circuit from TP24to the controller ORrepair open in brnground wire circuit fromground to controller.Re-adjust controller (seeRepair Section) ORreplace controller ORconsult Genie IndustriesService Department.4 to 6V