Part No. 65196 Genie S-60 & Genie S-65 5 - 47Third Edition • First Printing Section 5 • Troubleshooting Flow ChartsChart 21Platform LevelUp FunctionInoperativeBe sure all otherfunctions operatenormally.With key switch turnedto ground controls andboth Emergency Stopbuttons pulled out to theON position, hold thefunction enable switch toeither side and move theplatform level toggleswitch TS14 in the UPdirection. Check voltageat org-4 wire on platformlevel up directional valve(item T).0VWith key switch turnedto ground controls andboth Emergency Stopbuttons pulled out to theON position, hold thefunction enable switch toeither side and move theplatform level toggleswitch in the UPdirection. Check voltageat TB14.0VWith key switch turnedto platform controls andboth Emergency Stopbuttons pulled out to theON position, press downthe foot switch andmove the platform leveltoggle switch in the UPdirection. Check voltageat TB14.Repair open in org-4wire from TB14 toplatform level updirectional valve coil ORrepair open in brnground wire circuit tovalve coil.12V ormore0VTroubleshoot platformlevel toggle switchesTS14 and TS6 ORrepair open in red powerwire circuit to TS14 andTS6 OR repair open inorg-4 wire circuit fromTS14 and TS6 to TB14OR consult GenieIndustries ServiceDepartment.12V or moreTroubleshoot platformlevel toggle switch TS14OR repair open in redpower wire circuit toTS14 OR repair open inorg-4 wire circuit fromTS14 to TB14 ORconsult Genie IndustriesService Department.12V or moreContinued on the nextpage.