5 - 56 Genie S-60 & Genie S-65 Part No. 65196Third Edition • First PrintingSection 5 • Troubleshooting Flow ChartsChart 26Jib Boom UpFunctionInoperativeBe sure all otherfunctions operatenormally.With the key switchturned to groundcontrols and bothEmergency Stop buttonspulled out to the ONposition, hold thefunction enable switch toeither side and move thejib boom toggle switchTS19 in the UP direction.Check voltage at the grnwire on the jib boom updirectional valve(item BB).0V12VHold the function enableswitch to either side andmove the jib boomtoggle switch in the UPdirection and checkvoltage at TB17.12V0VRepair open in grn-4wire from TB17 to jibboom up directionalvalve OR repair open inbrn ground wire circuit todirectional valve.Repair open in redpower wire circuit fromkey switch to TS19 ORreplace TS19.With the key switchturned to platformcontrols and bothEmergency Stop buttonspulled out to the ONposition, press down thefoot switch and movethe jib boom toggleswitch TS24 in the UPdirection. Check voltageat TB17.12V0VPress down the footswitch and move the jibboom toggle switch inthe UP direction. Checkvoltage at TP17.Repair open in grn-3wire from TP17 to TB17.12V0VWith the key switchturned to platformcontrols and bothEmergency Stop buttonspulled out to the ONposition, press down thefoot switch and checkvoltage on the centerterminal of the jib boomtoggle switch.Check voltage atterminal #30 on CR13.0V12V Repair open in grn wirefrom TS24 to TP17 ORreplace TS24.0V12VRepair open in red wirefrom boom controller toCR13 OR repair open inbrn ground wire circuit toCR13.Check the voltage atterminal #87a on CR13.12V0V Replace CR13.Repair open in red wirefrom terminal#87a onCR13 to TS8 ORconsult Genie IndustriesService Department.Continued on the nextpage.