5 - 60 Genie S-60 & Genie S-65 Part No. 65196Third Edition • First PrintingSection 5 • Troubleshooting Flow ChartsSteer LeftFunctionInoperativeBe sure all otherfunctions operatenormally.Chart 28With key switch turnedto platform controls andboth Emergency Stopbuttons pulled out to theON position, press downthe foot switch and holdthe steer rocker switchon drive controller in theLEFT direction. Checkvoltage on TB36.0V12V or moreWith key switch turnedto platform controls andboth Emergency Stopbuttons pulled out to theON position, press downthe foot switch and holdthe steer rocker switchon drive controller in theLEFT direction. Checkvoltage at the controllerterminal with the bluwire attached.12V ormoreRepair open in blu wirecircuit from drivecontroller to TP36 thenblu-1 wire circuit toTB36.0VRepair or replace steermicroswitch on drivecontroller. ConsultGenie Industries ServiceDepartment.Continued on the nextpage.With key switch turnedto platform controls andboth Emergency Stopbuttons pulled out to theON position, press downthe foot switch and holdthe steer rocker switchon drive controller in theLEFT direction. Checkvoltage on blu #36 wireon steer left directionalvalve coil (item TT) onsteer manifold.12V or more0VRepair open in blu #36wire circuit from TB36 tosteer left directionalvalve coil on steermanifold OR repairopen in brn ground wirecircuit to steer leftdirectional valve coil.Disconnect wires tosteer left directionalvalve coil on steermanifold and test theresistance of the valvecoil.0 orinfiniteohmsReplace steer leftdirectional valve coil ORrepair open in brnground wire circuit tosteer left valve coil.5 to 6 ohms