©2011 The Genie Company9/2011 10ADJUSTMENT GUIDE - FORCE SETTINGSForce settings are pre-programmed at the factory and"learned" during the Open/Close Limit settings steps.For normal use, these settings should not need adjustmentwith this unit.However, conditions possibly requiring adjustment are:Doors with very stiff weather seals.Doors that start down, STOP and reverse before closing.Doors that start up, but STOP before they completely open.CAUTIONDoor closing force is FACTORY set and requires noadjustment for normal operation.s Never adjust the force settings to compensate for damage,including an unbalanced door, binding door track orbroken spring.s Perform monthly CONTACT REVERSELED indicator colors OFF Blue Purple Red1.2.3.ADJUSTMENT GUIDE - SPEED SETTINGSSpeed settings are pre-programmed at the factory for themaximum speed. Speed settings should not need adjustmentwith this unit.However, travel speed for the opener can be adjusted to aslower speed in both the open and close directions, Tomimimize wear on heavier sectional doors.NOTE: One-piece doors are automatically set to the slowestspeed during Limits programming and cannot be adjusted.There are 3 speed settings available for sectional doors.Please note that speed may be affected by door weight andbalance, along with condition of door components and tracks.TEST. See page 7.Press & holdboth up anddown buttons2 seconds or until roundLED turns Red.Press &Release.Press eitheruntil you reachdesired setting.FORCE SETTINGS DONEPROGRAMSETPress &Release.PROGRAMSETFORCE ADJUSTMENT12345USE CHART BELOW.Press eitheruntil youreach thedesired setting.USE CHART BELOW.LOCKS IN SETTING.LOCKS IN SETTING.OFFOFFSpeed Level Powerhead LEDsROUND LEDLONG LEDLED indicator colors OFF Blue Purple RedHighMediumLowREDREDPURPLE PURPLEACTION LED INDICATION/RESULTThen the Current UP FORCESETTING will display. SEE CHART.Then the CurrentDOWN FORCESETTING will display.Both LEDs TURNBLUE then OFFconfirms ForceSettings are reset.Both LEDs FLASHBLUE to confirm setting.Press &Release.Press twice.FORCE SETTINGS DONEPROGRAMSETPress & Hold forabout 10 secondsor until both LEDsturn Blue.Then release.PROGRAMSETPress &Release.PROGRAMSETSPEED ADJUSTMENT12345Press &Release.PROGRAMSETPress either untilyou reach thedesired setting.LOCKS IN OPENING SETTING.LOCKS IN CLOSING SETTING.OFFACTION LED INDICATION/RESULTThen the Current Speed settingfor OPENING travel will display.SEE CHART BELOW.Then the Current Speed settingfor CLOSING travel will display.SEE CHART BELOW.NOTE: Depending on the criteriamentioned above, you may nothave the option to increase speed.Press either untilyou reach thedesired setting.NOTE: Depending on the criteriamentioned above, you may nothave the option to increase speed.BLUEOFF RED OFF BLUEFLASHES 3 TIMESOFF FLASHES BLUE 3 TIMESBLUEBLUEBLUEFLASH BLUEFLASH BLUEBLUEBLUEBLUEBLUEFLASHESBLUE 3 TIMESOFFBLUEFLASHINGBLUE BLUE76Force Level Powerhead LEDsROUND LEDLONG LEDBLUEBLUEBLUE BLUEOffOffOffOffPURPLEPURPLEPURPLE PURPLEOffREDREDREDREDOff