136Interface cableThe FCM interface uses telephone cables with ferrite core.NOTE:The standard equipment package for the FIC-6FCM includes the appropriate number of interfacecables.Connecting the interface cableCAUTION:• Before connecting a port, read its label carefully. A wrong connection can cause damages to theinterface module and even the device.• Add a special lightning arrester at the input end of the telephone cable for better protection.To connect the interface cable:1. Connect one end of a telephone cable to the RJ-11 or RJ-45 connector of the FCM interface.2. Connect the other end of the telephone cable to PSTN network.Upgrading the FCM module software1. Download the FCM module software to the CF card or flash card of the router.2. After the router that is inserted with the FCM module is powered on and starts up, input bootromupdate file cfa0:/ filename slot slotnum all in the user mode to upgrade FCM module software.3. Run the display version command to display the driver version. If the version number ischanged, the upgrade is completed.The driver version number is just like (Driver) 1.0 in the module information displayed asfollows:[SLOT 5]MIM-6FCM (Hardware)1.0, (Driver)1.0, (Cpld)1.0FIC-1E1POSIntroductionThe 1-port E1 high-density POS access interface module (FIC-1E1POS) can deal with incomingcalls from 30 POS terminals at the same time by one E1 interface, and is applicable to the bank datatransaction center for smart card accounting management.