22HARDI® MUSTANG 3500 OPERATOR’S MANUALSpeed, Flow and RPM Transducer InstallationThe HARDI ® Mustang will work with either the magnetic speedtransducer or proximity speed transducer. DO NOT USE MAGNETSWITH THE PROXIMITY TRANSDUCER. Wiring remains the same foreither speed transducer. For magnetic transducers, the sensor needsto be placed 5-7 mm from the magnet. For proximity transducers, thesensor needs to be placed 1.5-3 mm from the magnet mount bracket(NO MAGNETS USED).Route the speed sensor cable to the HARDI ® Sprayer Control Module.Mate the wires as shown below. Be sure to slide a piece of heat shrinktubing over each individual wire before mating. Then shrink tubing byapplying heat evenly along tube. Plug the adapter cable into SprayerControl Module speed input pigtail with Yellow Cable Tie. DUPLICATETHIS FOR FLOW, AND RPM SENSOR INTERFACE.Blue RedBlackWhiteBrownBlackSpeed, Flowor RPMSensor3 wire adapter cableFor old infield sprayers, a magnet mount bracket may be required:10587803 – Magnet Mount Bracket 8-bolt16020203 – Magnet Mount Bracket 10-boltNote: the magnet mount brackets are used with both types of speedtransducers even though magnets are not used with the proximityspeed transducer.1058780316020203Proximity speed transducer