84 IBM : Hardware Maintenance Manual025-198-XXXIDE interface test aborted1. If a component is called out, make sure itis connected and/or enabled2. Flash the system and re-test3. Go to the "Undetermined problems"section025-199-XXXIDE interface test failed, cause unknown1. Go to the "Undetermined problems"section2. Flash the system and re-test3. Replace component under function test030-000-XXXSCSI interface Test Passed1. No action030-00X-XXX030-01X-XXXSCSI interface failure1. SCSI signal cable2. Check power supply3. SCSI device4. SCSI adapter card, if installed5. System board030-027-XXXSCSI interface Configuration/Setup error1. SCSI signal cable2. Flash the system3. SCSI device4. SCSI adapter card, if installed5. System board030-03X-XXX030-04X-XXXSCSI interface error1. SCSI signal cable2. Check power supply3. SCSI device4. SCSI adapter card, if installed5. installedSystem board030-195-XXXSCSI interface Test aborted by user1. Information2. Re-start the test, if necessary030-196-XXXSCSI interface test halt, error thresholdexceeded1. Press F3 to review the log file2. Re-start the test to reset the log file030-197-XXXSCSI interface test warning1. Make sure the component that is calledout is connected and/or enabled2. Re-run test3. Component that is called out in warningstatement4. Component under test030-198-XXXSCSI interface test aborted1. If a component is called out, make sure itis connected and/or enabled2. Flash the system and re-test3. Go to the "Undetermined problems"sectionDiagnostic Error Code FRU/Action