Table 4-1 (Page 9 of 11). Firmware Error CodesError Code Function /DescriptionRepair Action/Possible Failing FRU25AA0007 Unable to lockeepromRefer to EEPROM problem resolution aboveMemory errorsUse the location code obtained from the SMS Error Log utility (described in Map Step 1020-4) toidentify which memory DIMM the error is reported against.Memory error codes are in the form 25Cyyrrr where yy indicates Memory DIMM PD-bits and rrrindicates the last three digits of the error code.See “Memory PD Bits” on page 4-14 for information on how to interpret PD bits.25Cyy002 Memory DIMM failedmemory test1. Replace Memory DIMM2. Replace System PlanarSee “Memory PD Bits” on page 4-14 forinformation on how to interpret PD bits.PCI adapter problem26020001 Invalid PCI adapterVendor ID1. Move card to another slot2. Run AIX adapter diagnostics3. Replace card4. Update system firmware5. Replace power supply26020002 Invalid PCI adapterDevice ID1. Move card to another slot2. Run AIX adapter diagnostics3. Replace card4. Update system firmware5. Replace power supply26020003 Invalid PCI adapterClass Code1. Move card to another slot2. Run AIX adapter diagnostics3. Replace card4. Update system firmware5. Replace power supply26020004 Invalid PCI adapterROM VPD Structure1. Update card firmware2. Move card to another slot3. Run AIX adapter diagnostics4. Replace card5. Update system firmware6. Replace power supply26020005 PCI adapterfirmware is too largeto load1. Update card firmware2. Move card to another slot3. Run AIX adapter diagnostics4. Replace card5. Update system firmware6. Replace power supplyChapter 4. Error Code to FRU Index for the Model 150 4-9