Exception: If multiple error codes or light path diagnostics LEDs indicate amicroprocessor error, the error might be in a microprocessor or in a microprocessorsocket. See “Microprocessor problems” on page 51 for information about diagnosingmicroprocessor problems.If the server stops during testing and you cannot continue, restart the server and tryrunning the diagnostic programs again. If the problem remains, replace thecomponent that was being tested when the server stopped.Diagnostic text messagesDiagnostic text messages are displayed while the tests are running. A diagnostictext message contains one of the following results:Passed: The test was completed without any errors.Failed: The test detected an error.Aborted: The test could not proceed because of the server configuration.Additional information concerning test failures is available in the extendeddiagnostic results for each test.Viewing the test logTo view the test log when the tests are completed, type the view command in theDSA interactive menu, or select Diagnostic Event Log in the graphical userinterface. To transfer DSA collections to an external USB device, type the copycommand in the DSA interactive menu.Diagnostic messagesThe following table describes the messages that the diagnostic programs mightgenerate and suggested actions to correct the detected problems. Follow thesuggested actions in the order in which they are listed in the column.Chapter 3. Diagnostics 73