356 SCAN OPERATIONScan edges can be programmed in the same manner asmemory channels. Scan edges are programmed into scanedges, 0A/0B to 49A/49B, in memory channels.q Push the desired band’s [VFO/MR•S.MW] once or twiceto select VFO mode.w Set the edge frequency of the desired frequency range:➥ Set the frequency using the same band’s [DIAL].➥ Set other data (e.g. tone squelch, etc.), if desired.e Push and hold the same band’s [VFO/MR•S.MW] for1 sec. to enter select memory write mode.• “!” indicator and the memory channel number blink.r Rotate the same band’s [DIAL] to select one of scan edgechannel, 0A to 49A.t Push and hold [VFO/MR•S.MW] for 1 sec. to program.• 3 beeps sound and VFO mode is automatically selected.• Scan edge 0B to 49B is automatically selected when continuingto hold [VFO/MR•S.MW] after programming.y To program a frequency for the other pair of scan edges,0B to 49B, repeat steps w to r.• If the same frequency is programmed into a pair of scan edges,programmed scan will not function.[EXAMPLE]: Programming 144.000 MHz into scan edge 1A.Push Rotate for setting frequency, etc. Push for 1 sec.Rotate Push for 1 sec. and continue to push ➠BeepBeepBeepBeepBeepBeepS.MWVFO/MRS.MWVFO/MRS.MWVFO/MRRelease S.MWVFO/MR■ Scan edges programming