LT-200CL25Fig.35 No-shutter mode / Binning/ InternalFig.36 No-shutter /Sub-sampling and Window/ Internal6.4.2 No-shutter mode with external triggerIn this mode, the exposure time is directly proportional to the line rate. The line rate isgenerated externally by a trigger signal. This mode is used when an external trigger signalis available, e.g. from an encoder, and the scan rate can be controlled by this signal. Thecamera can accept an external trigger through the Camera Link connector or though the12-pin Hirose connector.To use this mode:Set function Trigger mode, No-shutter TR=0Trigger origin, external TG=1Trigger input TI=0 or 1