LT-200CL478.29 Command PGR – Run pixel gain correction and store in user areaThis command initiates the flat-field correction function, and stores the settings in theuser area.Settings: 0= Run PRNU correction and store to user areaAssociated functions: Command PGC must be set to 2Important note: The image sensors must not be saturated when executing this function. When executing this function, the exposure time and line rate should be the same aswhen the camera is operated in the application.Refer to chapter 6.3.8 PRNU (Pixel Response Non-Uniformity) correction for furtherdetails.8.30 Command PGS – Inquire the status after pixel gain correctionThis command returns the status of the pixel gain correction, with the followingparameters:0=Shading correction not completed yet1=Successful2=Error 1 – Image was too bright3=Error 2 – Image was too dark4=Error 3 - Timeout occurred8.31 Command SDC – Select shading correction modeThis function enables (or disables) the shading correction.Settings: 0 = off (Bypass)1 = Factory setting (default)2 = User areaAssociated functions: Command SDR8.32 Command SDR – Run shading correctionThis function initiates automatic shading correction, and stores the result to the userarea. This function should be used together with the flat-field correction (commandsPGC and PGR). There are two types of shading correction: Individual R, G and Bchannel correction and chromatic shading correction.Settings: 0=Run flat shading correction and store to user area1=Run color shading correction and store to user area(A) Flat shading correction (SDR=0)Shading is calculated and individually compensated for R, G and B channelsrespectively. The calculation is based on the average value of 8 consecutive pixels.The maximum deviation that can be compensated is -20% of the highest signal level(brightness) of the line.