LT-200CL286.4.3 Shutter-select mode with internal triggerThis mode allows the user to have full control of the line rate and the exposure timeindividually, by programming separate timing generators. Subsequently the camera does notaccept an external trigger signal in this mode.To use this mode:Set function Trigger mode, Shutter-select TR=1Line rate LR=32.9125μs to 16.844msTrigger origin, internal TG=0Individual R, G and B exposure EI=0(individual)EI=1(tracking with G)Programmable exposure PER/PEG/PEB=2064 to 1056720(25.8μs to 13.209ms in 12.5ns steps)Important note: If using individual exposure, the EEN signal represents the channel with the longest exposuretime The maximum exposure time is the line rate setting. For one-push white balance, both shutter gain (AH) and gain (AW) are effective.Fig. 40 Shutter-select mode with internal line rate generator (and individual exposure)Note: The largest exposure time is output as EEN.