LT-200CL326.4.5 Pulse width control (PWC) modeIn this mode, the user has full control of both the line rate and the exposure time of each linevia the External Trigger input.At the rising edge of the External Trigger signal, the exposure is initiated, and at the fallingedge the exposure is terminated and read out. The camera can accept an external triggerthrough the Camera Link connector or through the 12-pin Hirose connector.To use this mode:Set function Trigger mode, PWC TR=2Important Note: The minimum trigger intervalScan mode Trigger input via Minimum interval (μs)Full/Binning Camera link Exposure time + 33.4125Hirose 12-pin Exposure time + 37.9125Sub-sampling/windowing Camera link Exposure time + 20.6125Hirose 12-pin Exposure time + 25.1125 The minimum trigger pulse widthTrigger input via Minimum trigger pulse widthCamera link 33.4125μsHirose 12-pin 37.9125μs One-push white balance by gain setting only. When the one-push white balance has been initiated and the rear panel LED shows orange,the camera must receive continuous external trigger pulses corresponding to the frequencyand duty cycle used in the application.Fig. 46 Pulse Width Control mode