2524Procedure 16 - De-activate all Access Codes exceptMaster and ManagerYou may need to de-activate all users, for example, during a plant shut-down. This procedure will de-activate all regular User Access Codesthat are active, excluding Master and Manager Codes.Required User Level: Master, Manager1. Put the lock into Pushbutton Programming Mode.2. Enter Command 498# to de-activate all Access andService Codes.3. Example of Complete Entry: 498#.4. Enter another # to indicate the end of programming.5. You have now de-activated all regular User Access Codes.Procedure 17 - Activate/De-activate Lockout ModeYou may need to use Lockout Mode, for example, during a fire or firedrill when you do not want anyone to return to his or her office. Thisprocedure will de-activate all regular User Access Codes that are active,including Manager Codes, but excluding the Master Code.Required User Level: Master1. Put the lock into Pushbutton Programming Mode.2. Enter Command 499# for Lockout Users Mode (except Master).3. Enter 1# to activate Lockout Mode and 0# to disable it.4. Example of Complete Entry: 499#1# or 499#0#.5. Enter another # to indicate the end of programming.6. You have now activated or de-activated Lockout Mode.Procedure 18 - Perform Manual DiagnosticsUse the Diagnostic Code to perform manual diagnostics of the lock,green LED, red LED, buzzer, and the twelve pushbuttons - 0 through 9,* and #.Procedure 14 - De-activate Manager Access CodesA Manager Access Code should be de-activated for a certain time period- during a Manager’s vacation, for example, or if you created an AccessCode but never assigned it to a Manager. Manager Codes that might beneeded some time in the future should be de-activated rather than deleted.Required User Level: Master1. Put the lock into Pushbutton Programming Mode.2. Enter Command 401# to de-activate a Manager Access Code.3. Enter the code 401#NNN#, where NNN is the specific ManagerID location, 024 for example.4. Example of complete entry: 401#024#.5. Enter another # to indicate the end of programming.6. You have now de-activated a Manager Access Code.Procedure 15 - De-activate Service User Access CodeA Service User Access Code should be de-activated for a certain timeperiod - during a Service User’s absence, for example, or if you createdan Access Code but have not yet assigned it to a Service User. AService User’s time period continues to decrement if the User has onlybeen de-activated, not deleted.Required User Level: Master, Manager1. Put the lock into Pushbutton Programming Mode.2. Enter Command 402# to de-activate a Service User Access Code.3. Enter the code 402#NNN#, where NNN is the specific ManagerID location, 025 for example.4. Example of Complete Entry: 402#025#.5. Enter another # to indicate the end of programming.6. You have now de-activated a Service User Access Code.