983. Enter the code 009 #LL #, where LL represents the length(number of digits in a code). The range is from 04 to 08 digits.You can leave the factory default Access Code length(4 digits) if you wish.4. Example of Complete Entry: 009#05#.5. Key in another # to indicate the end of programming.6. From now on, all the Access Codes you create must be thelength specified in this step, which is 5 digits.Procedure 2 - Modify the Master User Access CodeRequired User Level: Master1. To change the factory code or current Master Code, follow thenext three steps:2. Put lock into Pushbutton Programming Mode.3. Use the command, 000, for Master, then the new MasterCode number.4. You must use 8 digits between 00000000 and 99999999 as follows:000#MMMMMMMM#, we’ll use 000#87654321# as an example.5. Enter the Master Code again 87654321# for confirmation.6. Example of Complete Entry: 000#87654321#87654321#.7. Key in another # to indicate the end of programming.8. After that, you will always use your own Master Code. Pleasewrite the code down and keep in a safe place. The factorycode is no longer valid.Required User Level: MasterProcedure 3 - Program the Unlock TimeUnlock time is the length of time the door will remain unlocked when acorrect code is entered before automatically re-locking itself.Required User Level: Master, Manager1. Put the lock into Pushbutton Programming Mode.2. To establish Unlock Time, enter the following code: 004#TT#,where TT is the time in seconds, (TT=02 to 20 seconds, forexample 10 seconds).3. Example of Complete Entry: 004#10#.4. Enter another # to indicate the end of programming.5. You have now programmed an Unlock Time of 10 seconds forthe door.Procedure 4 - Program the Duration of the PassageMode PeriodYou might want to program locks for public areas, such as cafeterias, tohave free access (Passage Mode) during certain periods of the day, andrevert to required code access outside of these regular hours.The length of time that the lock remains in Passage Mode is programmable.The factory default length of time for Passage Mode is 9 hours - you mayleave the default.Once the lock has been put into Passage Mode, it will automaticallyrelock after the designated duration.Required User Level: Master, Manager1. Put the lock into Pushbutton Programming Mode.2. Enter command code 005#.3. Then TT#, where TT= 01 to 24 hours.4. A TT entry of 00 means there is no time limit - the doorremains unlocked.5. Enter 005 #TT#; for example, 005#06# for six hours.6. Example of Complete Entry: 005#06#.7. Enter another # to indicate the end of programming.8. In this example, the lock will remain unlocked for six hours,starting from the time you put it in Passage Mode.9. You have now configured the duration of the Passage Modeperiod for that lock. This does NOT initiate Passage Mode.10. The new length of time will take effect the next time youput a lock into Passage Mode by following the correctcommand sequence.