1110Procedure 5 - Program the Lock for Tamper TimeParametersYou can set a Tamper Time Wrong Tries parameter referring to thenumber of times the wrong code can be entered before the lock goesinto Tamper Shutdown Mode.For example, if you program the lock to accept three wrong tries, thelock will tolerate three wrong entries, staying locked but providing visualfeedback (see visual message chart in rear section). After that, it will gointo a Tamper Shutdown Mode and remain locked until the end of theTamper Shutdown Time period - the length of that period is configured inSteps 1a through 1 c below.Required User Level: Master, Manager1. Set the tamper time for the period of time during which thekeypad will remain inaccessible after the specified numberof wrong Access Codes are entereda. Put the lock into Pushbutton Programming Mode.b. Enter the code as follows - 006#TT# (TT is seconds - 00 to90 seconds).c. Example of Complete Entry: 006#30#. (for 30 seconds)2. Enter the code as follows: 007 #TT# (TT is number of wrongentries - 03 to 09), let’s use 03 for example.a. Example of Complete Entry: 007#03#.b. Enter another # to indicate the end of programming.c. The lock will stay locked after three wrong entries for thelength of time you select in the steps below, even if a validcode (including the Master or a Manager Code) is enteredafter the three wrong codes. Only the mechanical keyoverride will open the lock during the lockout period.d. Enter another # to indicate the end of programming.In this example, the lock will now remain locked out for 30 seconds afterthree wrong Access Codes have been entered. No codes, even validones, will work in the lock until that time period has elapsed. During thistamper shut down period, the lock will flash the red LED once every 10secondsProcedure 6 - Programming the Lock for Keypad BuzzerVolumeYou might want to adjust the volume of the Keypad Buzzer dependingon where the lock is located - a noisy or quiet area.Required User Level: Master, Manager1. Put the lock into Pushbutton Programming Mode.2. Enter the code 008#VV# (where VV is a scale of volume from00 to 03; 00 = off; 01 = Low; 02 = Normal; 03 = High).3. Example of Complete Entry: 008#02#.4. Enter another # to indicate the end of programming.5. The lock will now sound the buzzer at the desired volumeNormal, until you change it.Users - General Information1. Master and Manager Codes can do two different things:• Open the door by entering the Access Code without # signs.• Put the lock into Pushbutton Programming Mode by entering# before and after their Access Code.2. Each user (Manager User, Service User or Access User) occupiesone of the available 100 locations in the user table.3. By default, user 000 is the Master User.4. Users have a 15-second period to enter the entire key sequence,and 5 seconds between pressing each pushbutton number. Ifthey pause longer than 5 seconds between each pushbuttonpressed, or exceed the 15-second period to enter the totalsequence, the lock:• aborts the current programming sequence• automatically exits the programming state• sends the user a ‘Keypad Timeout’ feedback message