22A7 MIG Welder©Kemppi Oy 2017 1735OPERATING MANUAL4.2.4 User settingsUser settings menu (Main menu 2/8) (login required)*Menu item Value range Factory value Description1/5 Change PINcodeChange your PIN code.New PIN code 0000 - 9999 0000 Specify a new PIN code.2/5 User mode ON, OFF OFF Set the user identification modeon and off.3/5 Set the userrightsChange the role for a user.Select user USER1 - USER10 Select the user whose role youwant to change. Note! You cannotchange your own role.Level Welder,Supervisor,AdministratorSelect the role for the user.4/5 User activation Create and delete users.User activation USER1 - USER10 Select the user account that youwant to create /delete.User Enabled,DisabledCreate an account by settingthe user Enabled, or delete theaccount by selecting Disabled.5/5 Reset user PINcodeReset the PIN code of a user.Select user USER1 - USER10 Select the user whose pin codeto reset. The reset value is 0000.Confirm the reset by pressing OKsoft button.* See section 4.4 User identification for more information.4.2.5 Welding system settingsSystem config menu (Main menu 4/8)Menu item Value range FactoryvalueDescription1/20 Water cooling OFF, ON, AUTO AUTO Set the water cooler on andoff, or let the system controlthe cooler (AUTO). In automode the water pump startswhen welding starts andstops after a delay whenwelding stops.2/20 Cable length 10 - 100 m 10 m Set the welding circuit lengthfor optimal arc control.3/20 FineCalib 0 V - 10 V /100 A10 V / 100 A Set the compensation forcable resistance variation.4/20 System clock View and modify the systemtime and date.5/20 Device information Review the following deviceinformation for each devicein the system:DevSW: Unit softwareversion.SysSW: System base softwareversion.BootSW: Boot softwareversion.SW Item: Software itemnumber.Serial: Device serial number.Prog: Programmer name.Date: Programming date.6/20 Restore settingsROBOT All settings All memory channels (0-199)are restored from backup.Setup settings remain as theyare.Restore to factory All memory channels andtheir backups are removed.All settings are set to defaultfactory values.