66TK-5710(B)/5710H(B)ADJUSTMENTMeasurement AdjustmentItem Condition Test- Unit Terminal Unit Parts Method Specifications/Remarksequipment12. MSK 1) Adj item:[W MSKW] Power meter Rear ANT Front [PF3], 3.0kHz ±100Hzdeviation Adjust:[***] Deviation panel panel [PF4]adjust Deviation meter filter meter•Wide LPF:15kHz Oscilloscope Front MIC jackHPF:OFF AG panelPTT:ON AF VTVMPress [PF5] to store the adjust-ment value after adjustment.•Narrow 2) Adj item:[N MSKN] 1.5kHz ±50HzAdjust:[***]PTT:ONPress [PF5] to store the adjust-ment value after adjustment.13. Single tone 1) Adj item:[W 2TNW] 3.0kHz ±100Hzdeviation Adjust:[***]adjust Deviation meter filter•Wide LPF:15kHzHPF:OFFPTT:ONPress [PF5] to store the adjust-ment value after adjustment.•Narrow 2) Adj item:[N 2TNN] 1.5kHz ±50HzAdjust:[***]PTT:ONPress [PF5] to store the adjust-ment value after adjustment.Measurement AdjustmentItem Condition Test- Unit Terminal Unit Parts Method Specifications/Remarksequipment1. RX [Panel tuning mode] SSG Rear ANT Front [PF3], Enter the following Note: After replacing theFront-end 1) Adj item:[W FEND] panel panel [PF4] adjustment values EEPROM (IC701)adjust Adjust:[***] to the transceiver align RX Front-end.2) Adj item:[WL FEND]t by pressing [PF3][WLC FEND]t[WC FEND]t and [PF4] keys.[WCH FEND]t[WH FEND] [WL FEND] : 190[WLC FEND] : 160[WC FEND] : 110[WCH FEND] : 65[WH FEND] : 10After setting theadjustment value,press [PF5] key.The adjustmentvalue will be storedin memory.Receiver Section