D-24 APPENDIX D General Setup, Configuration and TroubleshootingSeries 5000 Sonar System Operations and Maintenance Manual P/N 11210060, Rev. 13.0D.5 TPU LAN Configuration SetupConnect a Terminal or PC running HyperTerminal to COM1 on the back of theTPU.Configure the device as follows:• 9600 baud• 8 bit• 1 stop bit• none flow control• VT100 emulationConfigure the ASCII setup in the ASCII Setup dialogbox, and then connect the TPU to the host PCcomputer using the Ethernet Hub.Turn on the TPU. The CPU in the TPU will look for the host computer and loadthe file vxWorks:VxWorks System BootCopyright 1984-2001 Wind River Systems, Inc.CPU: Motorola MVME5110-2161 - MPC 7410Version: VxWorks5.4.2BSP version: 1.2/2Creation date: Aug 29 2006, 10:17:52Press any key to stop auto-boot...0auto-booting...boot device : feiunit number : 0processor number : 0host name : sonarclientfile name : \klein\vxWorksinet on ethernet (e) : 192.168.0.81host inet (h) : 192.168.0.82