61Using Each Operation Management FunctionFor executing the operation management such as monitoring failures on the server, NECESMPRO Agent and NEC ESMPRO Manager, or software sold separately is required.Follow the instruction of the setup procedure described later or the description of the software(when sold separately) to install and set each software.Make sure to confirm the following points when using each operation management function.Using Server Management Function● Setting threshold values, etc, on NEC ESMPRO Manager and on NEC ESMPRO Agent isrequired depending on the monitoring items such as the usage monitoring of each component ofthe server or the stall monitoring of OS. Refer to the descriptions of each software or online helpfor details.●When DIMMs in the server are changed and the voltage of the DIMMs are different from previousones, NEC ESMPRO Agent is needed to be uninstalled once and installed again.Consult the maintenance service company for details.●When the setting of the ambient temperature is changed and the version of ManagementFirmware is 3.1.0.7 or after, NEC ESMPRO Agent is needed to be uninstalled once and installedagain.(The version of 3.1.0.6 does not exist)Follow the steps as below or consult the maintenance service company for details.1) Uninstall NEC ESMPRO Agent2) DC power off for all servers.3) Update the managemenet firmware to version of 3.1.0.7 or after if it is 3.1.0.5 or before.4) Change the setting of the ambient temperature5) DC power on for all servers6) Install NEC ESMPRO Agent