5450. Audio Select RequestFunctionThe external control equipment inquires the current combinations of audioand video inputs for the plasma monitor.Transmission Data1FH 80H 60H 6FH 00H CKSACKThe plasma monitor returns the following ACK:7FH 60H 80H 6FH 03H DATA00 DATA01 DATA02 CKSDATA00: AUDIO 101H – 0CH: VISUAL INPUT DATADATA01: AUDIO 201H – 0CH: VISUAL INPUT DATADATA02: AUDIO 301H – 0CH: VISUAL INPUT DATAVISUAL INPUT DATA01H: Video 102H: Video 203H: Video 305H: HD (HD1 or DTV or DTV 1)06H: HD2 (DTV2)07H: RGB 1 /PC 108H: RGB 2 /PC 20CH: RGB 3 /PC 351. Failure Mode RequestFunctionThe external control equipment inquires the detection of failures of the plasmamonitor.Transmission Data1FH 80H 60H 3FH 00H CKSACKThe plasma monitor returns the following ACK:7FH 60H 80H 3FH 02H DATA00 DATA01 CKSDATA00: FAILURE MODE 1Bit 0 : PDP MODULE0: Abnormal1: NormalBit 1 : 1: fixed (backup)Bit 2 : TEMPERATURE0: Abnormal1: NormalBit 3 : FAN0: Abnormal1: NormalBit 4 : 1: fixed (backup)Bit 5 : 1: fixed (backup)Bit 6 : 1: fixed (backup)Bit 7 : 1: fixed (backup)DATA01: FAILURE MODE 2Bit 0–7 : 1: fixed (backup)52. MODEL NAME RequestFunctionThe external control equipment inquires the product code of the plasma monitor.Transmission Data1FH 80H 60H 17H 00H CKSACKThe plasma monitor returns the following ACK:7FH 60H 80H 17H 0CH DATA00 to DATA11 CKSDATA00 : 1st character of the product codeDATA01 : 2nd character of the product codeDATA11 : 12th character of the product codeNOTE:Received data (Hex) Corresponding character00H 001H 108H 809H 910H A11H B12H C28H Y29H Z80H - (Hyphen)96H (Blank)If there are fewer than 12 characters in the product code, product code wouldbe padded right with blanks.Example: If the product code of your plasma monitor is “PX-50XM2A”, the returned codes would be as follows.DATA00: 1FHDATA01: 27HDATA02: 80HDATA03: 05HDATA04: 00HDATA05: 27HDATA06: 1CHDATA07: 02HDATA08: 10HDATA09: 96HDATA10: 96HDATA11: 96H