Program 81 : Basic Hardware Setup for Trunk81-01 : CO Initial Data SetupLevel:INDescriptionUse Program 81-01 : CO Initial Data Setup to define the various basic data parameters for theCOIU.Input DataItemNo.Item Input Data Default01 PCM Encoding Method Specifica-tion0 = μ-law1 = A-law0 (μ-law)02 Loop Current Detection Time 1 ~ 255(10 ~ 2550 ms)60 (600 ms)03 Clear Signal (Open Loop) Detec-tion Time1 ~ 255(5 ~ 1275 ms)61 (305 ms)04 Ringing Signal Detection MinimumTime1 ~ 255(10 ~ 2550 ms)10 (100 ms)05 Single Ringing Detection MinimumTime0 ~ 255(0, 10 ~ 2550 ms)66 (660 ms)06 Double Ringing Detection Mini-mum Off Time0 ~ 255(0, 10 ~ 2550 ms)10 (100 ms)07 Double Ringing Detection Maxi-mum Off Time0 ~ 255(0, 10 ~ 2550 ms)40 (400 ms)08 Ringing Signal not Detection Mini-mum1 ~ 255(10 ~ 2550 ms)70 (700 ms)09 Time Ringing Signal Stop Detec-tion Time1 ~ 255(100 ~ 25500 ms)60 (6000 ms)10 Continuous Ringing MinimumTime0 ~ 255(0, 10 ~ 2550 ms)30 (300 ms)11 Continuous Ringing MaximumTime0 ~ 255(0, 10 ~ 2550 ms)70 (700 ms)14 Hook Flash 1 Time 1 ~ 255(10 ~ 2550 ms)80 (800 ms)15 Hook Flash 2 Time 1 ~ 255(100 ~ 25500 ms)25 (2500 ms)16 Pause Time 1 ~ 255(100 ~ 25500 ms)10 (1000 ms)17 PFT Idle Detection Time 1 ~ 255(100 ~ 25500 ms)30 (3000 ms)20 Loop Reverse Detect MinimumTime1 ~ 255(10 ~ 2550 ms)10 (100 ms)21 Loop Reverse Detect MaximumTime1 ~ 255(10 ~ 2550 ms)86 (860 ms)22 Loop Disconnect Detect MinimumTime1 ~ 255(10 ~ 2550 ms)40 (400 ms)ISSUE 6.0 SL1100Programming Manual 2-467Program81