Program 90 : Maintenance Program90-11 : Alarm Report SMTP SettingLevel:INDescriptionUse Program 90-11 : Alarm Report SMTP Setting to define the details of the system alarm report.Input DataItemNo.Item Input Data Description Default RelatedProgram02 Report Method 0 = No Report1 = E-mail AddressWhen alarm reports are e-mailed,set this option to 1. E-mail addressset in 90-11-08.006 SMTP Host Name Up to 255 Characters When alarm reports are e-mailed,set the SMTP name (ex : smtp.your-isp.com). Contact your ISP (internetservice provider) for the correct en-try if needed.No Setting07 SMTP Host PortNumber0 ~ 65535 When alarm reports are e-mailed,set the SMTP host port number.Contact your ISP (internet serviceprovider) for the correct entry if nee-ded.2508 To E-mail Ad-dressUp to 255 Characters When alarm reports are e-mailed,set this e-mail address to which thereport should be sent.No Setting09 Reply Address Up to 255 Characters When alarm reports are e-mailed,set the e-mail address where repliesshould be e-mailed.No Setting10 From Address Up to 255 Characters When alarm reports are e-mailed,set this e-mail address for the sta-tion sending the report.No Setting11 DNS Primary Ad-dress0.0.0.0 ~255.255.255.255When alarm reports are e-mailed,set the DNS primary address.0.0.0.012 DNS SecondaryAddress0.0.0.0 ~255.255.255.255When alarm reports are e-mailed,set the DNS secondary address.0.0.0.013 Customer Name Up to 255 Characters When alarm reports are e-mailed,enter a name to identify the particu-lar system.No Setting14 Use StandardSMTP Settings(V2.0 Added)0 = No1 = YesIn case of YES uses a PRG47-18SMTP client.( MEMDB/CF mountingis required.)To Address (PRG 90-11-08), CCMail Address (PRG 90-25-01) Up to48 characters.In case of No uses a PRG 90-11SMTP client.0 90-11-0890-25-0147-1890-11ISSUE 6.0 SL1100Programming Manual 2-549Program90