ENW415-1710 / A / 07.27.1725installation planning4.2 installation option 2 - front openingSuitable for Dynamic Heat Control™ PlusMINIMUM AIR OUTLET OPENING DIMENSIONSLVX38 LVX50 LVX62 LVX74(Q x R)* 80 sq. in. minimum (Q must be 2-3”) 160 sq. in. minimum (Q must be 2-3”)S This dimension is determined from the enclosure height (L) minus the distance to the top of the DynamicHeat Control™ air outlet opening (0”-1.5”), height of the air opening (2”-3”), and the distance from thebase of the appliance to the top of the appliance viewing area (25 11/16”).*Free area. Any trim edging or finishing must not reduce or restrict minimum area. Grills, grates, louvres, orother unapproved covers are not permitted and will cause a fire hazard.Wall mountedobject (pictureframe, appli-ance, etc.)ceilingenclosure topmust be installed2-3”0-1.5” Max6” minAir outlet opening is required to be centered with the appliance.ALTERNATIVE(Q x R)*DYNAMIC HEATCONTROL™ AIROUTLET OPEN-ING IS HOT WHENAPPLIANCE ISOPERATING!Front air outlet opening mustbe located out of reach of theuser. Air outlet must not berestricted by furnishings ordecor.Minimum air outlet opening dimensions must be followed. The opening is required to be framed no more than 1.5” below theenclosure top (see option 2 diagram) to avoid trapping heat in the upper areas and the air outlet opening centered on the appliancecenter. Framing the air outlet opening lower will overheat the appliance, the enclosure, and finishing material.SL2 1/2”min