PICO Toμch Controller12www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.SpecificationsNOTE: Specifications and technical details are subject to engineering change without prior notification.Item SpecificationCabinet size 14.2W x 13.3H x 16.8D cm ( 28 Hp x 3U)5.6W x 5.25H x 6.6D"Weight 2.6 kg (5.5 lb)Material Aluminum / steelInput AC (to power supply) 100–240 VAC +/-10%, 50–60 Hz, 2 AmpOutput DC (from power supply) 24 VDC, 6.25 AmpInternal voltage 150 VDC, 24 VDC, 5 VDC, and 3.3 VDCHeater output voltage 24 VDC, 30 W maximumFeedback circuit 0–24 VDCInitiate circuit 15–24 VDC (must be a clean, bounce-free signal)Heater outputs Setpoint range: 0–100° C; 0.1° C incrementsTemperature input type at valve: RTDIndication accuracy: ±1° CSample rate: 60 per secondControl method: PIDNOTE: No valve cooling is possible.Cycle rate Valve-dependentTime range 100 μs to 9.9999 s (depending on the open profile time)Ambient operating conditions Temperature: 5–45° C (41–133° F)Humidity: 85% relative humidity at 30° C (86° F), non-condensingHeight above sea level: 2000 m (6,562 ft) maximumIndoor use onlyProduct classification Installation category IIPollution degree 2Approvals CE, RoHS, WEEE, and China ROHS compliantRoHS标准相关声明 (China RoHS Hazardous Material Declaration)产品名称Part Name有害物质及元素Toxic or Hazardous Substances and Elements铅Lead(Pb)汞Mercury(Hg)镉Cadmium(Cd)六价铬HexavalentChromium(Cr6)多溴联苯PolybrominatedBiphenyls(PBB)多溴联苯醚PolybrominatedDiphenyl Ethers(PBDE)外部接口External ElectricalConnectorsX 0 0 0 0 0O:表示该产品所含有的危险成分或有害物质含量依照EIP-A,EIP-B,EIP-C的标准低于SJ/T11363-2006限定要求。Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is belowthe limit requirement in SJ/T11363-2006.X: 表示该产品所含有的危险成分或有害物质含量依照EIP-A,EIP-B,EIP-C的标准高于SJ/T11363-2006限定要求.Indicates that this toxic or hazardous substance contained in all the homogeneous materials for this part, according to EIP-A, EIP-B, EIP-C is abovethe limit requirement in SJ/T11363-2006.WEEE DirectiveThis equipment is regulated by the European Union under WEEE Directive (2012/19/EU). Refer to www.nordsonefd.com/WEEE for information about how to properly dispose of this equipment.