PICO Toμch Controller32www.nordsonefd.com info@nordsonefd.com 800-556-3484 Sales and service of Nordson EFD dispensing systems are available worldwide.Adjusting the Valve Operating Parameters(PULSE, CYCLE, or COUNT)Follow this procedure to adjust how the valve operates, includingvalve open time (PULSE), time between deposits (CYCLE), andnumber of deposits per cycle (COUNT). For more information on theseparameters, refer to "VALVE Screen" on page 19.1. Press the VALVE icon ( ).2. Press PULSE, CYCLE, or COUNT. A numeric keypad appears fordata entry.3. Enter the desired setting for PULSE, CYCLE, or COUNT.• PULSE: How long the valve stays opens (in ms).• CYCLE: Amount of time between deposits (in ms).• COUNT: Number of deposits per cycle.4. Press OK (check) > HOME to save the setting and return to theHOME screen.Setup and Programming Procedures (continued)Switching Valve Power On or OffFollow this procedure to set whether a valve initiate signal is processed.Valve initiate signals are processed only when valve Power is ON.NOTE: By default, valve POWER is ON when the controller is switchedON (or anytime the controller is rebooted). To change the valvePOWER setting default, refer to "Appendix A, Remotely Operating theController" on page 53.1. Press the VALVE icon ( ).2. Press POWER until the touchscreen shows the desired valve powerstatus.• On: Valve closed; valve initiate signals processed.• Off: Valve open; valve initiate signals NOT processed.3. Press HOME to save the setting and return to the HOME screen.ABOUT CALENDARCLOCK SET OK (check) LANGUAGE RAMPBackspace Cancel HEATERS LOCKOUTS SETTINGSLCD SETTINGS Decimal Point HOME PASSWORDS SYSTEMCYCLE Decrement Increment PURGE VALVE