76 Chapter 2 System Diagnostics and StatisticsDisplaying stack monitor configuration parameters valuesUse the show stack-monitor command to display the currentconfiguration values for the stack monitor.Parameter DescriptionStatus Enabled or disabled.Stack size Number of units in the stack <2-8>. Default value is 2.Trap interval Number of seconds between traps <3-300>. Default value is 60seconds if there are 2 units in the stack.Configuring stack monitor parametersUse the config stack-monitor command to configure the stackmonitor.Configuring stack monitor parametersParameter Descriptionenable/disable Enable or disable stack monitoringstack-size Set stack size to be monitored <2-8>trap-interval Set interval between traps (seconds) <3-300>Configuring stack monitor parameters with the JDMTo configure stack monitor parameters with the JDM, click Edit > Chassis >Stack Monitor.Configuring the stack monitor with the JDMConfiguring stack monitor parametersParameter DescriptionStackErrorNotificationEnabled Enable or disable stack monitoringExpectedStackSize Set stack size to be monitored <2-8>StackErrorNotificationInterval Set interval between traps (seconds) <3-300>Click Apply to apply new settings.Nortel Ethernet Routing Switch 5500 SeriesConfiguration - System MonitoringNN47200-505 03.01 Standard5.1 27 August 2007Copyright © 2005 - 2007, Nortel Networks.