Configuring RMON with the CLI 91rmon alarm parametersParameter Description<1-65535> Unique index for the alarm entry. The MIB object to be monitored. This is an objectidentifier, and for most available objects, an Englishname may be used.<1-2147483647> The sampling interval, in seconds.absolute Use absolute values (value of the MIB object iscompared directly with thresholds).delta Use delta values (change in the value of the MIB objectbetween samples is compared with thresholds).rising-threshold<-2147483648-2147483647 >[<1-65535>]The first integer value is the rising threshold value. Theoptional second integer specifies the event entry tobe triggered when the rising threshold is crossed. Ifomitted, or if an invalid event entry is referenced, noevent will be triggered.falling-threshold<-2147483648-2147483647 >[<1-65535>]The first integer value is the falling threshold value.The optional second integer specifies the event entryto be triggered when the falling threshold is crossed.If omitted, or if an invalid event entry is referenced, noevent will be triggered.[owner ] Specify an owner string to identify the alarm entry.The rmon alarm command is executed in the Global Configurationcommand mode.no rmon alarmThe no rmon alarm command deletes RMON alarm table entries. Whenthe variable is omitted, all entries in the table are cleared.The syntax for the no rmon alarm command is:no rmon alarm [<1-65535>]Substitute <1-65535> above with the unique ID of the alarm entry.The no rmon alarm command is executed in the Global Configurationcommand mode.rmon eventThe rmon event configures RMON event log and trap settings.The syntax for the rmon event command is:Nortel Ethernet Routing Switch 5500 SeriesConfiguration - System MonitoringNN47200-505 03.01 Standard5.1 27 August 2007Copyright © 2005 - 2007, Nortel Networks.