18 Chapter 2 SRG50 overviewNN40140-500NN40140-500To reboot the system1 In Element Manager, navigate to the Reset panel (Administration > Utilities > Reset).2 Click Reboot BCM50 System.To verify that the SRG has been successfully created1 In Element Manager, navigate to the Keycodes panel (Configuration > System > Keycodes).In the Feature licenses table, verify that the status of the SRG keycode is ACTIVE.2 Open the Resources folder (Configuration > Resources).Verify that there is a Survivable Remote Gateway panel.SRG50 and BCM50 features comparisonThe table Comparison of BCM50 and SRG50 on page 18 compares SRG50 and BCM50 features.Table 5 Comparison of BCM50 and SRG50 (Sheet 1 of 2)Item BCM50 SRG50MBMs See theInstallation andMaintenanceGuide(NN40020-302)Recommended:ASM8+ (8 port Analog Station Module); DTM(Digital Trunk Module - 24 lines on either T1or E1 or PRI); BRI (4 line BRI S/T Module);GATM4 (Global Analog Trunk MBM - 4 port);GATM8 (Global Analog Trunk MBM - 8 port)ADID4 (4 analog lines)ADID8 (8 analog lines)G4x16 (16 digital ports and 4 analog trunks);G8x16 (16 digital ports and 8 analog trunks)Supported for ATA connections:DSM16 (Digital Station Module - 16 ports);DSM32 (Digital Station Module - 32 ports);4x16 Combo (16 digital ports, 4 analogtrunks and 1 analog station);Does not support:DDIM (Digital Drop and Insert Mux)FEM (Fiber Expansion Module)DECT (Digital Enhanced CordlessTelecommunications)Digital telephone sets Yes NoFCAPS Yes Yes, extended to include SRG-specificalarms and keycodesNetwork Configuration Manager Yes YesTelset Administration Yes NoCS 1000 Geographic Redundancy N/A YesCS 1000 Network Bandwidth Management N/A Yes