-ML182/183 _________________ _Speed9600480024001200600300150110Switch 6:-Switch 2 Switch 3 Switch 4-ON ON ON-OFF ON ONON OFF ONOFF OFF ONON ON OFF-OFF ON OFFON OFF OFF -OFF OFF OFFFactory set in the ON position; this setting allows theprinter to receive data with parity (the way mostpopular personal computers transmit data).NOTE: Switches not mentioned in the list above are not currently used and should beleft in their factory settings.If you have the know-how and the necessary tools and equipment tomake your own cable, here is what you will need:1. A-25 conductor cable. We recommend a shielded cable consisting of 22 Awe standard wires not to exceed 10 feet inlength.2. One 25-pin plug: equivalent to Cannon DB25-P for the IBMside.3. One 36-pin plug: equivalent to Amphenol 57-30360 for theprinter side.4. Wire the pins on the 25-pin plug to those on the 36-pin plug asshown below:-120