16ConnectionsO Use the AW-PS505 (optional accessory) for the mainunit’s AC adapter and the AW-PS300 (optionalaccessory) for the pan-tilt head’s AC adapter.O Connect the DC 12V IN socket on the control panel withthe CONTROL PANEL POWER OUT connector on themain unit, and the CONTROL OUT connector on thecontrol panel with the CONTROL IN TO CONTROLPANEL connector 1 on the main unit using the cables (10m) supplied.To extend the connection distance between the controlpanel and main unit beyond 10 meters, the AW-PS505(optional accessory) as the power supply for the controlpanel and a 10BaseT straight cable (for the controlsignals) must be provided separately.The maximum extension distance is 500 meters when the10BaseT straight cable (equivalent to UTP category 5) isused.O Use a DC power cable (which has a nominal cross-sectional area of at least 1.25 mm2 and which complieswith the Electrical Appliance and Material Control Law) toconnect the AW-PH350 pan-tilt head and AW-PS300pan-tilt head AC adapter.The maximum extension distance between the ACadapter for the pan-tilt head and the pan-tilt head itself is30 meters.O Connect the AW-PH350 pan-tilt head and convertiblecamera using the composite camera cable (AW-CA50T29) or component camera cable (AW-CA50C29).O Connect the iris control cable of the motorized zoom lensto the camera and the remote (zoom/focus control) cableto the pan-tilt head.When using composite signalsO The AW-CA50T29 (optional accessory) is required toconnect the convertible camera to the AW-PH350 pan-tilthead.O To connect the main unit and pan-tilt heads, use twocoaxial cables (one for the video signals and the other forthe G/L signals) and one 10BaseT straight cable (for thecamera/pan-tilt head control signals) for each pan-tilthead.The maximum extension distance is 1,000 meters foreach pan-tilt head (when coaxial cables equivalent toBELDEN 8281 and a 10BaseT straight cable equivalentto UTP category 5 are used).When using component signalsO The AW-CA50C29 (optional accessory) is required toconnect the convertible camera to the AW-PH350 pan-tilthead.O To connect the main unit and pan-tilt heads, use fourcoaxial cables (one each for the Y signals, Pr signals, Pbsignals and G/L signals) and one 10BaseT straight cable(for the camera/pan-tilt head control signals) for eachpan-tilt head.The maximum extension distance is 1,000 meters foreach pan-tilt head (when coaxial cables equivalent toBELDEN 8281 and a 10BaseT straight cable equivalentto UTP category 5 are used).O When component signals are used, the RGB card (AW-PB302) available as an optional accessory must beinstalled in the convertible camera.Turn off the power of all components beforeproceeding with the connections.For further details on how to connect each component,refer to the operating instructions of the componentconcerned.