113. SpecificationsIndoor Model CS-DZ25VKE CS-DZ35VKEOutdoor Model CU-DZ25VKE CU-DZ35VKEPerformance Test Condition EUROVENT EUROVENTPower Supply Phase, Hz Single, 50 Single, 50V 230 230Min. Mid. Max. Min. Mid. Max.CoolingCapacitykW 0.85 2.50 3.00 0.85 3.40 3.90BTU/h 2900 8530 10200 2900 11600 13300kcal/h 730 2150 2580 730 2920 3350Running Current A – 3.05 – – 4.90 –Input Power W 250 690 910 255 1.10k 1.30kAnnual Consumption – 345 – – 550 –EER CLASS – A – – B –EERW/W 3.40 3.62 3.30 3.33 3.09 3.00BTU/hW 11.60 12.36 11.21 11.37 10.55 10.23kcal/hW 2.92 3.12 2.84 2.86 2.65 2.58ErPPdesign kW 2.5 3.4SEER (W/W) 5.8 5.6AnnualConsumption kWh 151 213Class A+ A+Power Factor % – 98 – – 98 –Indoor Noise (H / L / QLo) dB-A 37 / 26 / 20 38 / 30 / 20Power Level dB 53 / – / – 54 / – / –Outdoor Noise (H / L / QLo) dB-A 48 / – / – 48 / – / –Power Level dB 64 / – / – 64 / – / –HeatingCapacitykW 0.80 3.15 3.60 0.80 3.84 4.40BTU/h 2730 10700 12300 2730 13100 15000kcal/h 690 2710 3100 690 3300 3780Running Current A – 3.45 – – 4.60 –Input Power W 195 770 1.03k 195 1.04k 1.27kCOP CLASS – A – – A –COPW/W 4.10 4.09 3.50 4.10 3.69 3.46BTU/hW 14.00 13.90 11.94 14.00 12.60 11.81kcal/hW 3.54 3.52 3.01 3.54 3.17 2.98ErPPdesign kW 1.9 2.4Tbivalent °C -10 -10SCOP (W/W) 4.1 4.1AnnualConsumption kWh 649 820Class A+ A+Power Factor % – 97 – – 98 –Indoor Noise (H / L / QLo) dB-A 37 / 27 / 24 38 / 33 / 25Power Level dB 53 / – / – 54 / – / –Outdoor Noise (H / L / QLo) dB-A 49 / – / – 50 / – / –Power Level dB 64 / – / – 65 / – / –Low Temp. : Capacity (kW) / I.Power (W) / COP 2.61 / 910 / 2.87 3.19 / 1.12k / 2.85Extr Low Temp. : Capacity (kW) / I.Power (W) / COP 2.14 / 850 / 2.52 2.60 / 1.03k / 2.52Max Current (A) / Max Input Power (W) 4.8 / 1.03k 7.0 / 1.58kStarting Current (A) 3.45 4.90