8914.10 Quiet Operation (Heating)A. PurposeTo provide quiet heating operation compare to normal operation.B. Control conditiona. Quiet operation start conditiono When “POWERFUL/QUIET” button at remote control is pressed twice. QUIET will be shown on remotecontrol display.b. Quiet operation stop condition1 When one of the following conditions is satisfied, quiet operation stops:a. POWERFUL/QUIET button is pressed again.b. Stop by OFF/ON switch.c. Timer “off” activates.d. When FAN SPEED button is pressed.2 When quiet operation is stopped, operation is shifted to normal operation with previous setting.3 When operation mode is changed, quiet operation is shifted to quiet operation of the new mode.4 During quiet operation, if timer “on” activates, quiet operation maintains.5 After off, when on back, quiet operation is not memorized.C. Control contentsa. Fan Speed manual1 Fan speed is changed to Lo-.b. Fan Speed Auto1 Fan speed is changed to Lo-.14.11 Powerful Mode Operation When the powerful mode is selected, the internal setting temperature will shift lower up to 2°C (for Cooling/SoftDry) or higher up to 3.5°C (for Heating) than remote control setting temperature for 20 minutes to achieve thesetting temperature quickly.