9716.2.2 Operation mode during Heating only Operation The table below shows the operation mode comparison when Heating Only Operation Mode Activated andDeactivated.Operation Mode Heating Only Operation Mode Activated Heating Only Operation Mode DeactivatedAUTOAfter 30s sampling, regardless of the indoor intake oroutdoor intake temperature judgment, the unit will runHeating operation.After 30s sampling, the unit will judge the operationmode base on remote controller temperature setting andIndoor Intake Sensor (New Auto Mode) or OutdoorIntake Sensor (Old Auto Mode).HEAT The unit will run Heating operation. The unit will run Heating operation.COOL The unit will stop and Power LED blinking. The unit will run Cooling operation.DRY The unit will stop and Power LED blinking. The unit will run Cooling Dry operation.NANOE-GStand-alone The unit will stop and Power LED blinking. The unit will run Nanoe-G Stand-alone operation.Force Cooling The unit will run Force Cooling Operation for X_CTRYTM [15]minutes The unit will run Force Cooling operation.Force Heating The unit will run Force Heating operation. The unit will run Force Heating operation.AUTO(with Timer)The unit will turn ON by the timer and run Auto Operation. After30s sampling, regardless of the indoor intake or outdoor intaketemperature judgment, the unit will run Heating operation.The unit will turn ON by the timer and run Auto Operation. After30s sampling, the unit will judge the operation mode base onremote controller temperature setting and Indoor Intake Sensor(New Auto Mode) or Outdoor Intake Sensor (Old Auto Mode).HEAT(with Timer) The unit will turn ON by the timer and run Heating Operation. The unit will turn ON by the timer and run Heating Operation.COOL(with Timer) The unit will not turn ON by the timer. Power LED blinking. The unit will turn ON by the timer and run Cooling Operation.DRY(with Timer) The unit will not turn ON by the timer. Power LED blinking. The unit will turn ON by the timer and run Cooling DryOperation.CoolingTest Mode The unit will stop and Power LED blinking. The unit will operate according to specify Cooling test modeoperation parameter.HeatingTest ModeThe unit will operate according to specify Heating test modeoperation parameter.The unit will operate according to specify Heating test modeoperation parameter.16.3 Remote Control Button16.3.1 SET Button To check remote control transmission code and store the transmission code to EEPROM:o Press “Set” button by using pointer.o Press “Timer Set” button until a “beep” sound is heard as confirmation of transmission code changed. To limit set temperature range for COOL & DRY, HEAT mode.o Press “Set” button by using pointer.o Press TEMP increment or decrement button to choose No. 3.o Press Timer increment or decrement button to select desired temperature low limit of set temperature forCOOL & DRY mode.o Press Timer Set button to confirm low limit selection.o Press TEMP increment or decrement button to choose No. 4.o Press Timer decrement or increment button to select desired temperature high limit of set temperature forCOOL & DRY mode.o Press Timer Set button to confirm high limit selection.o Press TEMP increment or decrement button to choose No. 5.o Press Timer increment or decrement button to select desired temperature low limit of set temperature forHEAT mode.o Press Timer Set button to confirm low limit selection.o Press TEMP increment or decrement button to choose No. 6.o Press Timer decrement or increment button to select desired temperature high limit of set temperature forHEAT mode.o Press Timer Set button to confirm high limit selection.o LCD returns to original display if remote control does not operate for 30 seconds or press Timer Cancelbutton.16.3.2 RESET (RC) To clear and restore the remote control setting to factory default.o Press once to clear the memory.