5512.2.4 Connect the Cable to the Indoor UnitThe power supply cord, indoor and outdoor unit connection cable can be connected without removing the front grille.1 Install the indoor unit on the installing holder that mounted on the wall.2 Open the front panel and grille door by loosening the screw.3 Cable connection to the power supply through Isolating Devices (Disconnecting means).o Connect the approved polychloroprene sheathed power supply cord 3 × 1.5 mm2 (1.0 ~ 1.5HP) or3 × 2.5 mm2 (2.0HP), type designation 60245 IEC 57 or heavier cord to the terminal board, and connectthe other end of the cable to Isolating Devices (Disconnecting means).o Do not use joint power supply cord. Replace the wire if the existing wire (from concealed wiring, orotherwise) is too short.o In unavoidable case, joining of power supply cord between isolating devices and terminal board of airconditioner shall be done by using approved socket and plug rated 15/16A (1.0 ~ 1.5HP) or 16A (2.0HP).Wiring work to both socket and plug must follow to national wiring standard.4 Bind all the power supply cord lead wire with tape and route the power supply cord via the left escapement.5 Connection cable between indoor unit and outdoor unit shall be approved polychloroprene sheathed4 × 1.5 mm2 (1.0 ~ 1.5HP) or 4 × 2.5 mm 2 (2.0HP) flexible cord, type designation 60245 IEC 57 or heaviercord. Allowable connection cable length of each indoor unit shall be 30 m or less6 Bind all the indoor and outdoor connection cable with tape and route the connection cable via the rightescapement.7 Remove the tapes and connect the power supply cord and connection cable between indoor unit and outdoorunit according to the diagram below.• How to pull the piping and drain hose out, in case of theembedded piping. • In case of left piping how to insert theconnection cable and drain hose.Rear view for left piping installationDrain cap Drain hoseAdjust the piping slightlydownwards.Drain hoseConnection cablePVC tubefor drainhoseIndoor unit100 mm (1.0 ~ 1.5HP) or72 mm (2.0HP)PipingCableApply putty orcaulking materialto seal the wallopening. Connection cablePipingMore than470 mmMore than 950 mmPVC tube (VP-65) for pipingand connection cablePVC tube for drain hose (VP-30)PVC tube for drainhose (VP-20)More than 700 mmDrain hosefrom main unitExchange the drain hose and capCable45°DrainhosePipingSleeve for piping holeDrain hosePipingConnection cableMore than 950 mm(For the right piping, follow the sameprocedure)321tinuroodtuoehtnoslanimreTColour of wires (connection cable)Terminals on the indoor unit L N 1 2 3(Power supply cord)Terminals on the isolatingdevices (Disconnecting means) (L) (N)