14719.2 Heat Mode Performance DataUnit setting: Standard piping length, Hi Fan, Heat mode at 30°CVoltage: 230V19.2.1 CS-PZ25VKE CU-PZ25VKE CS-DZ25VKE CU-DZ25VKEIndoor (°C) Outdoor WB (°C)DB -15 -7 2 7 12TC IP TC IP TC IP TC IP TC IP24 1803 802 2016 904 2553 927 3039 812 3137 81920 1714 796 2140 850 2610 910 3150 770 3351 81816 1800 748 2074 873 2653 858 3189 749 3471 78219.2.2 CS-PZ35VKE CU-PZ35VKE CS-DZ35VKE CU-DZ35VKEIndoor (°C) Outdoor WB (°C)DB -15 -7 2 7 12TC IP TC IP TC IP TC IP TC IP24 2026 915 2449 1096 3121 1140 3705 1097 3824 110620 1925 908 2600 1030 3190 1120 3840 1040 4085 110516 2023 853 2520 1057 3242 1056 3888 1012 4231 105619.2.3 CS-PZ50VKE CU-PZ50VKE CS-DZ50VKE CU-DZ50VKEIndoor (°C) Outdoor WB (°C)DB -15 -7 2 7 12TC IP TC IP TC IP TC IP TC IP24 3604 1897 4169 2103 5275 2110 5043 1572 5368 156420 3609 1795 4580 2090 5430 2160 5400 1570 5584 156416 3401 1699 4723 2001 5465 2056 5765 1568 5919 156119.2.4 CS-UZ25VKE CU-UZ25VKEIndoor (°C) Outdoor WB (°C)DB -15 -7 2 7 12TC IP TC IP TC IP TC IP TC IP24 1803 802 1960 883 2485 906 2894 781 2987 78720 1714 796 2080 830 2540 890 3000 740 3191 78616 1800 748 2016 852 2581 839 3037 720 3306 75219.2.5 CS-UZ35VKE CU-UZ35VKEIndoor (°C) Outdoor WB (°C)DB -15 -7 2 7 12TC IP TC IP TC IP TC IP TC IP24 2026 915 2393 1085 3052 1130 3570 1055 3684 106420 1925 908 2540 1020 3120 1110 3700 1000 3936 106316 2023 853 2462 1047 3171 1047 3746 973 4077 1016