291 JAN 2006Ver. 5.2DP-3510/3520/3530/4510/4520/4530/6010/6020/60308 Options and Supplies8.1. Service Notes "Firmware Update" for PCL-IPX/SPX or PS-IPX/SPXOption Installation (For DP-3530/4530/6030)To use PCL-IPX/SPX (DA-PC602) or PS-IPX/SPX (DA-MC602) option individually or in combination withother options, changing to Type B or Type D SC firmware is required. The required firmware is on the CDincluded with the options.Note:The DA-EM600 must be installed for the printer controllers above to function. The only time a DA-EM600is needed is if you are installing the Postscript (PS) or PCL option. There will never be a need for 2 ofthese, even if there are other options, such as fax, added.Before proceeding, it is important to determine the Final Configuration of your machine in order to correctlyidentify the required firmware from the table below. Carefully read and follow the Installation Instructions forthe appropriate option.The firmware for SC, SPC and PNL must be updated in this sequence as a set. Please update the firmwarewith the latest version as a set by referring to the following table.Firmware Version Table (For DP-3530/4530/6030)Standard Firmware(SC = Type A)PCL Firmware(SC = Type B)PostScript Firmware(SC = Type D)SC SFD_M25RAxVxxxxx-xx SFD_M25RBxVxxxxx-xx SFD_M25RDxVxxxxx-xxPNL M25R_PNLAxVxxxxx-xx ← ←SPC SFDM_SPCAxVxxxxx ← ←Slot 1 FROM PCB Not Required Required Required