Tone TimingsDescription Specifies the pattern, in milliseconds, of reorder tones using 8 wholenumbers (on 1, off 1, on 2, off 2, on 3, off 3, on 4, off 4) separated bycommas.Value Range 0–5000 (0: Infinite time)Default Value 250,250,250,250,250,250,250,250Configuration File Reference REORDER_TONE_TIMING (Page 182)3.7.4.6 Howler ToneTone FrequenciesDescription Specifies the dual-tone frequencies, in hertz, of howler tones (i.e., alarmtones) using 2 whole numbers separated by a comma.Value Range 0, 200–3000 (0: No tone)Default Value 1400,2060Configuration File Reference HOWLER_TONE_FRQ (Page 182)Tone TimingsDescription Specifies the pattern, in milliseconds, of howler tones (i.e., alarm tones)using 4 whole numbers (on 1, off 1, on 2, off 2) separated by commas.Value Range 0–5000 (0: Infinite time)Default Value 100,100,100,100Configuration File Reference HOWLER_TONE_TIMING (Page 183)Start TimeDescription Specifies the length of time, in seconds, that busy or reorder tones playuntil they switch to howler tones.Value Range 0–120 (0: Disable)Default Value 30Configuration File Reference HOWLER_START_TIME (Page 183)3.7.5 Import PhonebookThis screen allows you to import phonebook data from a PC to the specified unit. For details, see 5.2.1 Import/Export Operation.Document Version 2013-02 Administrator Guide 1213.7.5 Import Phonebook