Value Range • Y (Enable periodic synchronization of configuration files)• N (Disable periodic synchronization of configuration files)Default Value NWeb User Interface Reference Cyclic Auto Resync (Page 150)CFG_CYCLIC_INTVLValue Format IntegerDescription Specifies the interval, in minutes, between periodic checks for updatesof the configuration files.Value Range 1–40320Default Value 10080Web User Interface Reference Resync Interval (Page 151)CFG_RTRY_INTVLValue Format IntegerDescription Specifies the period of time, in minutes, that the unit will retry checkingfor an update of the configuration files after a configuration file accesserror has occurred.Note• This setting is available only when "CFG_CYCLIC" is set to "Y".Value Range 1–1440Default Value 30CFG_RESYNC_TIMEValue Format StringDescription Specifies the time (hour:minute) that the unit checks for updates ofconfiguration files.Value Range 00:00–23:59Note• If the value for this setting is any valid value other than an emptystring, the unit downloads the configuration files at the fixedtime, and the settings specified in "CFG_CYCLIC","CFG_CYCLIC_INTVL", and "CFG_RTRY_INTVL" aredisabled.• If the value for this setting is an empty string, downloading theconfiguration files at the fixed time are disabled.Default Value Empty stringDocument Version 2013-03 Administrator Guide 1855.3.5 Provisioning Settings