ADJ-11SECTION 3 ADJUSTMENTS < RZ31K/RS30K>1. 4. Lens calibration1. Select sub menu [LENS CALIBRATION] of [PROJECTOR SETUP] menu.2. Select the used lens type.• NORMAL : When using the other than ET-D75LE95• D75LE95 : When using the ET-D75LE95 (ultra short throw lens)PROJECTROR SETUP 2/3DATE AND TIMESCHEDULENORMALOFFOFFDEFAULTMULTI PROJECTOR SYNCRS-232CREMOTE2 MODEFUNCTION BUTTONLENS CALIBRATIONLENS MEMORYSTATUSAC VOLTAGE MONITORFILTER SETTINGSAVE ALL USER DATACHANGESETENTERD75LE95LENS CALIBRATION3. A confirmation message is displayed and select [OK].LENS CALIBRATIONOK CANCELCHANGEEXECUTEENTERProceed LENS CALIBRATION,and return to HOME POSITION.4. The lens will move vertically/horizontally and backward/frontward to detect the limit value of the lens shift and focus, andsetup the home position automatically.5. After finishing the calibration, the main menu will be displayed.1. 5. Model information setup1. Enter the service mode, and select submenu [MODEL] of [EXTRA OPTION]menu.2. Select the model and press the [ENTER] button.3. The model information will be applied after the main power restart.4. Confirm the model information in the sub menu [STATUS] of the menu [PRO-JECTOR SETUP].MODELWUXGA :RZ31KSXGA+ :RS30KD WUXGA :RZ31KDSXGA+ :RS30KDJ WXGA :RZ31KJSXGA+ :RS30KJC WUXGA :SRZ31KCSXGA+ :SRS30KCMENU SELECTSETENTER