Part names and functions10 Operation flowchartMode switching operation tableController panel display Mode name How to switch from AUTO modeAUTO AUTO mode Set by default when the power is turned onMNL *1 Manual (MNL) mode (EMISSION start) Hold down MODE switch.MNL flashing *2 External manual (MNL) mode (External start)Turn on the signal to INPUT terminal “MNL ON”on the rear panel. (Cannot be switched to anothermode while MNL is flashing.)ALL/MULTI Irradiation mode MNL mode + One press of MODE switchPULSE/STATUS Start signal mode MNL mode + Two presses of MODE switchX100hs LED replacement time setting mode MNL mode + Three presses of MODE switchW/cm2 UV intensity measurement/calibration mode MNL mode + Four presses of MODE switchTYPE Product type setting switch mode MNL mode + Five presses of MODE switchPROG Program setting mode MNL mode + Six presses of MODE switchPWR Power mode ON/OFF switch mode MNL mode + Seven presses of MODE switch*1 In manual mode (EMISSION start), it is possible to externally start irradiation by turning on the external signal to “MNL ON”.(MNL indicator will be turned on.)*2 In external manual mode (external start), it is possible to start irradiation by pressing EMISSION on the controller. (MNLindicator will flash.)Flowchart Power onAUTOMNLALL/MULTIPULSE/STATUSX100hrsW/cm2TYPEPROGPWRAUTO mode(Page 19)Mode nameManual (MNL) mode(Page 23)Irradiation mode(Page 26)Start signal mode(Page 27)LED replacementtime setting mode(Page 27)Product type settingswitch mode(Page 30)Program settingmode(Page 30)Power modeON/OFF switchmode(Page 32)External MNL ONExternal manual(MNL) mode(Page 26)UV intensitymeasurement/calibration mode(Page 28)