Operation modes196.1 Auto mode (Set by default when the power is turned on) Status checkDisplays in AUTO modeDisplay DescriptionsEMISSION switchPressing it will start irradiation.Stays on during irradiation.READYIndicates that irradiation is ready to start.Stays on while irradiation is ready to start.Stays off during irradiation.Indicates the channel connection, irradiationoperation, and temperature warning.Green: Indicates that the head is connected.Orange: Indicates a temperature warning.Red flashing: Indicates that irradiation is inprogress.Flashes during irradiation, changing theflashing speed depending on the detectedtemperature of the LED head.CH1 to 4ERROR Lit when an error occurs.PWR Stays on while the power mode is on.Display (2 digits) Displays the product type no. (TYPE00 to15) and the step no. (STEP 01 to 10).Display (3 digits)Displays the UV intensity level (0 to 100%),LED head temperature (0 to 999), andirradiation time (0 to 99.9, 100 to 999 sec.).% Stays on while the 3-digit display indicatesthe UV intensity level.sec. Stays on while the 3-digit display indicatesthe irradiation time.x100hrs Lit when the total irradiation time reachesthe warning point.CH1 to 4switchesLit when the channel is selected.Lit to indicate that the channel is selected forthe product type.Flashes while the 3-digit display indicatesthe STEP 1 data.Flashing speed LED head temperatureOff No irradiationSlow StandardMid Standard ≤ Temp. < Warning levelQuick Warning level ≤ Temp. < Abnormal