19ON: Enables the PLAYBACK AUTO mode.OFF: Disables the PLAYBACK AUTO mode.5. PASSWORDThis item lets you select whether to permit free or limitedaccess to the Setup menus. When PASSWORD is set toON, the operator must enter the password to access themenus.1. Move the cursor to the PASSWORD parameter.2. Select ON or OFF by pressing the + or – button.The initial factory setting is OFF.5-1. Password registrationEnter a 4-digit password consisting of numbers from 1 to 9(except 0).ON→1111-9999:Password required to access the Setup menus.1. Select ON by pressing the + or – button.2. Move the cursor to the desired (first) digit by press-ing the A or B button.3. Select the desired number by pressing the + or –button.4. Repeat steps 2 and 3 until all digits are registered.OFF: No password required to access the Setupmenus (access is free).5-2. Reply to password requestIf PASSWORD parameter is set to ON, the operator isrequested to type the password to access the Setupmenus.1. Press the MENU/ESC button for 2 seconds or more.The password inquiry screen prompts you to type thepassword.2. Type the 4-digit password by pressing the CAMERASELECT buttons 1 through 9, and the A or B button.3. The Setup menu appears if the typed password is cor-rect. If a wrong password is typed, the screen displays“NG” and returns to the screen before the MENU/ESCbutton was pressed.4. To retry repeat steps 1 and 2.5-3. Changing the passwordThe password currently registered can be changed as fol-lows.1. Press the MENU/ESC button for 2 seconds or more todisplay the password inquiry screen. Then type in thecurrent password by pressing the CAMERA SELECTbuttons, and the A or B button. The SETUP menuappears.2. In the SYSTEM SETUP menu, select ON for the PASS-WORD parameter.3. Move the cursor to the first (desired) digit by pressingthe A or B button.4. Select the desired number by pressing the + or – but-ton.5. Repeat step 3 and 4 until all digits are registered.6. After registration the new password is required whenthe operator accesses the SETUP menus.6. PWR ON MULTIThis parameter lets you select a multiscreen output patternfor your startup screen. When the power is turned on, thepicture is displayed in the selected pattern.1. Move the cursor to the PWR ON MULTI parameter.2. Select 1-16 (1-9 only for WJ-FS309/FS409), SPOT SEQor QUAD-4A to 4D, 9 screen, 16 screen, MLT-SEQThe initial factory setting is QUAD-4A.1-16: Spot picture of selected channel is displayed.SPOT SEQ: A sequence of spot pictures is displayed.QUAD-4A to 4D: 4-segment screen9 screen: 9-segment screen16 screen: 16-segment screenMLT-SEQ: Multiscreen sequence7. PWR ON SPOTThis parameter lets you select a Spot output pattern foryour startup screen. When the power is turned on, the pic-ture is displayed in the selected pattern.1. Move the cursor to the PWR ON SPOT parameter2. Select 1-16 (1-9 only for WJ-FS309/FS409) or SPOTSEQ.The initial factory setting is 1.1-16: Spot picture of selected channel is displayed.SPOT SEQ: A sequence of spot pictures is displayed.