• The data sent from a PC to the unit through port 52000 of the UDP can be sent to the camera throughRS485 to control the camera.[RS485 transmission]Select “On” or “Off” to determine whether or not to control the camera using RS485.• Default: On[Communication method]Select the communication method of the RS485 cable from 4-line and 2-line.• Default: 4-line[Baud rate]Select the line speed for RS485 transmission from the following.2400bps/4800bps/9600bps/19200bps/38400bps• Default: 19200bps[Data bit]Select the data bit from 7bit or 8bit.• Default: 8bit[Parity check]Select from the following to determine whether or not to perform the parity check.None/Odd/Even• Default: None[Protocol]Select the RS485 control command for the camera from the following.Panasonic/Pelco-D/Pelco-P/Custom• Default: PanasonicNote• When using RS485 control commands other than Panasonic, Pelco-D, and Pelco-P, select “Custom”for “Protocol” and upload the command table to the unit via an FTP server. The unit must be rebootedafter the upload is completed.• If Pan/Tilt/Zoom functions cannot be operated for Panasonic cameras, you must select “Custom” for“Protocol” and upload the command table to the unit. For further information, refer to our website(http://panasonic.net/pss/security/support/info.html).• Refer to our website (http://panasonic.net/pss/security/support/info.html) for further information abouthow to upload command tables and cases when RS485 cannot control cameras.42 Operating Instructions8 Configure the settings relating to images [Image]