44Connection with PS·Data systemsThis is an example of connection when the unit is used together with the PS·Data devices.If a connected system controller is PS·Data compatible, it is possible to operate this unit or connected devices using the sys-tem controller.Use the RS485 cable provided with the system controller.Important:• Terminate both devices on both ends of the connection. Refer to the respective operating instructions for the descriptionsof how to terminate. Termination of this unit can be set with the mode selection DIP switch on the rear panel. (See page47.)• When connecting a PS·Data compatible device, it is necessary to set each item of "PS.Data Setup" of "CommunicationSetup" according to the system configuration.• The following are available PS·Data compatible devices.• System controller: WV-CU650 (Ver 2.10 or later)• Data multiplex unit: WJ-MP204• Matrix switcher: WJ-SX650 (Ver. 3.00 or later)(Any other PS·Data compatible devices are not to be connected.)When connecting a single unit with a controllerAUX INAUDIO OUTINOUT16 15 14 13 12 11 10 9 8 7 6 5 4 35 3 16 4 21214 13 12 11 10 9 8 7 6 5 4 3 2 116 15MONITOR1 MONITOR2RS485(CAMERA)MODE1 2DATA 10/100BASE-T COPY1 ALARM IN/CONTOROL AUDIO IN SIGNAL GNDPOWERONOFFAC INAUDIO IN/ALARM OUTVIDEOSERIALThis unit1ON2Mode selectionDIP switchesA B1 324 657 980SYSTEM CONTROLLERControllerTermination: ONUnit Address: 1RS485 cable(provided with the controller)"PS.Data Setup" of "Communication Setup"on the Setup Menu• Unit Address (System): 1• Unit Address (Controller): 2