62Configure the settings relating to the camera control [Camera ControlSetup]Configure the communication type for the camera control and the cable compensation setting for each channel. TypeSelect a camera control method from the following.Coax: Control the camera using the coaxial communica-tion. (Cam 1 - 8 are available (Cam 5-8 are availableonly when an optional board is installed).)RS485: Control the cameras using the RS485 communica-tion.Off: Do not control the cameras.Default: Coax (Cam 1 - 4), PSD (Cam 5 - 16) ProtocolSelect "Panasonic" when "RS485" is selected for "Type".Default: Panasonic CompensationSelect the cable length when "Coax." is selected for "Type".(Cam 1 - 8 are available (Cam 5-8 are available only whenan optional board is installed).)It is necessary to configure to control the camera using thecoaxial communication.S: Suitable when the total cable length between the cameraand the recorder is shorter than 500 mM: Suitable when the total cable length between the cam-era and the recorder is 500 - 900 mL: Suitable when the total cable length between the cameraand the recorder is 900 - 1 200 mDefault: SNotes:• To display the "Camera Control Setup" page for camerachannels 9-16, click the [9-16] button.• The setting of compensation (cable loss) will be ignoredwhen receiving any alarm from cameras during commu-nication setup.Important:Stop recording before changing the settings relating tothe camera control. Otherwise, the cable compensationsetting (Comp.) may not be saved.Camera Control SetupType Protocol CompensationOK9 - 16 CancelCam 1 CoaxCoaxCoaxCoaxPSDPSDPSDPSDPanasonicPanasonicPanasonicPanasonicPanasonicPanasonicPanasonicPanasonicCam 2Cam 3Cam 4Cam 5Cam 6Cam 7Cam 8SSSSSSSSCamera Control SetupType ProtocolOK1 - 8 CancelCam 9 PSDPSDPSDPSDPSDPSDPSDPSDPanasonicPanasonicPanasonicPanasonicPanasonicPanasonicPanasonicPanasonicCam 10Cam 11Cam 12Cam 13Cam 14Cam 15Cam 16